On November 4, 2026, NVD received five more critical CVEs on consumer routers: two on the Linksys E5350, two on the venerable Linksys WRT54GL, and one on the Comfast CF-WR632AX. VulDB filed all of them as CNA, every one has a public exploit, and each description says the vendor was contacted and did not respond.

CVEDeviceVersion citedFlawPrivileges (vector)CVSS 3.1 (VulDB)
CVE-2026-121933Linksys E53501.0.00.037Missing authentication (CWE-306)none10.0
CVE-2026-121932Linksys E53501.0.00.037OS command injection (CWE-78)none10.0
CVE-2026-122013Comfast CF-WR632AX2.6.0.1Path traversal (CWE-22)none10.0
CVE-2026-121931Linksys WRT54GL4.30.18OS command injection (CWE-78)high9.1
CVE-2026-121930Linksys WRT54GL4.30.18OS command injection (CWE-78)high9.1

All five entries are in NVD status Deferred, meaning NVD won't prioritize analyzing them, and none carries a CPE configuration. None is in the CISA KEV catalog at the time of writing.


Linksys E5350 — a full chain inside the setup wizard

Both CVEs target the same file, /wizard/apply.cgi, which belongs to the initial setup wizard, on firmware 1.0.00.037. Both carry the vector AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H (10.0).

CVE-2026-121933: in the save_settings function, manipulating the wizard_router_pwd argument leads to missing authentication (CWE-287, CWE-306). The researcher's repository cited in the references is titled "empty admin password auth bypass", so the scenario is an admin password left blank through the wizard.

CVE-2026-121932: in the system function of the same file, the ping_ip and traceroute_ip arguments end up in an OS command injection (CWE-77, CWE-78). The reference repository calls it "preauth", meaning it works without logging in, which the PR:N in the vector confirms.

Put together, these two flaws give an attacker who can reach the interface both control of the admin account and command execution on the router. Unlike the WRT54GL entries, the E5350 descriptions do not say the product is out of support. They only say Linksys didn't respond.

Linksys WRT54GL — two injections on an unsupported product

Same pattern, this time in the WRT54GL's apply.cgi on firmware 4.30.18: the system function, through the traceroute_ip argument (CVE-2026-121931, traceroute diagnostic) and ping_ip (CVE-2026-121930, ping diagnostic). OS command injection in both cases.

The vector is AV:N/AC:L/PR:H/UI:N/S:C/C:H/I:H/A:H (9.1), so an administrator account is required. On a router still running factory credentials, that's not much of a barrier.

The description is explicit: the flaw only affects products that are no longer supported. No fix is coming.

Comfast CF-WR632AX — CVE-2026-122013

Vector: AV:N/AC:L/PR:N/UI:N/S:C/C:H/I:H/A:H (10.0)

A path traversal (CWE-22) in /usr/bin/webmgnt, in the multipart parser, through the filename argument, on firmware 2.6.0.1. The multipart parser handles file uploads, and a filename containing ../ lets a request read or write outside the intended directory. The description doesn't say whether it's a read or a write. The 10.0 score, with integrity and availability rated High, suggests at least a write, but that's a reading of the vector, not something the description states.


What these flaws mean

  • No fix announced. No description mentions a fixed version, and neither vendor answered the researcher.
  • Three of the five need no authentication. For those, the only barrier is whether the admin interface is reachable.
  • Public exploits on GitHub for all five.
  • Linksys again. This is the second batch in two days, after the Linksys E5600 covered in our November 4 article.

Detection

  • Admin interface exposed on the WAN: check this first, from outside
  • Requests to /wizard/apply.cgi (E5350) or apply.cgi (WRT54GL) with shell characters (;, |, $(, backticks) in ping_ip or traceroute_ip
  • Setup wizard replayed on an already configured router, or admin password changed for no reason
  • Multipart uploads to the Comfast with ../ in the filename
  • Outbound traffic initiated by the router to unknown destinations, changed DNS settings or port forwards

Mitigation

  1. Disable remote (WAN) administration on all three models. Without a fix, this is the most effective measure.
  2. Replace the WRT54GL: it's unsupported and no fix is coming.
  3. Linksys E5350: make sure a strong admin password is actually set, and restrict interface access to the wired LAN.
  4. Comfast CF-WR632AX: limit access to the web interface and watch the vendor site for firmware newer than 2.6.0.1 that lists this CVE.
  5. In a business setting: these routers don't belong at the edge of a corporate network. In branch offices or home-working setups, isolate them from the internal network.

Why continuously monitor your routers

Five more critical CVEs with no fix, on routers people forget about once they're plugged in. Knowing which ones run on your network, and on which firmware, is the only way to react in time.

With cveo.tech, inventory your routers with their model and firmware, and get alerted as soon as a critical CVE affects them.

Know which CVEs hit the versions you run.

Add the product and its version: cveo.tech lists the CVEs that affect it right away, then alerts you by email when a new one affects it — including before NVD has finished its analysis. Free, an account is all it takes.

Every Monday

The week's critical CVEs, in your inbox

One email a week: the CVSS ≥ 9 vulnerabilities published in the last seven days, plus our latest analyses. Nothing else.

Double opt-in by email. Unsubscribe in one click, any time.